Parameter

Mechanical Parameters

ItemSpecification
CellMono
Weight32.5 kg
Dimensions2333±2mm × 1134±2mm × 30±1mm
Cable Cross Section Size4mm² (IEC), 12 AWG (UL)
No. of cells144 (6×24)
Junction BoxIP68, 3 diodes
ConnectorQC 4.10-351 / MC4-EVO2A
Cable Length (Including Connector)Portrait: 300mm(+) / 400mm(-)
Landscape: 1400mm(+) / 1400mm(-)
Front Glass/Back Glass2.0mm / 2.0mm
Packaging Configuration36pcs/Pallet, 720pcs/40HQ Container
Remark: customized frame color and cable length available upon request


Electrical Parameters at STC

TypeJAM72D40-590/LBJAM72D40-595/LBJAM72D40-600/LBJAM72D40-605/LBJAM72D40-610/LBJAM72D40-615/LB
Rated Maximum Power(Pmax) [W]590595600605610615
Open Circuit Voltage (Voc) [V]52.0052.2052.4052.6052.8053.00
Maximum Power Voltage (Vmp) [V]43.4143.5943.7643.9444.1144.28
Short Circuit Current(Isc) [A]14.3514.4214.4814.5314.5714.61
Maximum Power Current(Imp) [A]13.5913.6513.7113.7713.8313.89
Module Efficiency [%]22.322.522.722.923.123.2
Power Tolerance0~+3%
Temperature Coefficient of Isc (α_Isc)+0.045%/°C
Temperature Coefficient of Voc (β_Voc)-0.250%/°C
Temperature Coefficient of Pmax (γ_Pmp)-0.290%/°C
STC: Irradiance 1000W/m², cell temperature 25°C, AM1.5G
Remark: Electrical data in this catalog do not refer to a single module and they are not part of the offer. They only serve for comparison among different module types.


Electrical Characteristics with 10% Solar Irradiation Ratio

TypeJAM72D40-590/LBJAM72D40-595/LBJAM72D40-600/LBJAM72D40-605/LBJAM72D40-610/LBJAM72D40-615/LB
Rated Max Power(Pmax) [W]637643648653659664
Open Circuit Voltage (Voc) [V]52.0052.2052.4052.6052.8053.00
Max Power Voltage (Vmp) [V]43.4143.5943.7643.9444.1144.28
Short Circuit Current(Isc) [A]15.5015.5715.6415.6915.7415.78
Max Power Current(Imp) [A]14.6814.7414.8114.8714.9415.00
Irradiation Ratio (rear/front): 10%
*For Nextracker installations, maximum static load please take compatibility approve letter between JA Solar and Nextracker for reference.


Operating Conditions

ItemSpecification
Maximum System Voltage1500V DC
Operating Temperature-40°C~+85°C
Maximum Series Fuse Rating30A
Maximum Static Load, Front*5400Pa (112 lb/ft²)
Maximum Static Load, Back*2400Pa (50 lb/ft²)
NOCT45±2°C
Bifaciality80%±5%
Safety ClassClass II
Fire PerformanceUL Type 29/Class C