| Technical Specification | SUN2000-2KTL-L1 | SUN2000-3KTL-L1 | SUN2000-3.68KTL-L1 | SUN2000-4KTL-L1 | SUN2000-4.6KTL-L1 | SUN2000-5KTL-L1 | SUN2000-6KTL-L1 |
|---|---|---|---|---|---|---|---|
| Efficiency | |||||||
| Max. efficiency | 98.2% | 98.3% | 98.4% | 98.4% | 98.4% | 98.4% | 98.4% |
| European weighted efficiency | 96.7% | 97.3% | 97.3% | 97.5% | 97.7% | 97.8% | 97.8% |
| Input (PV) | |||||||
| Recommended max. PV power ¹ | 3,000 Wp | 4,500 Wp | 5,520 Wp | 6,000 Wp | 6,900 Wp | 7,500 Wp | 9,000 Wp |
| Max. input voltage | 600 V | ||||||
| Startup voltage | 100 V | ||||||
| MPPT operating voltage range | 90–560 V | ||||||
| Rated input voltage | 360 V | ||||||
| Max. input current per MPPT | 12.5 A | ||||||
| Max. short-circuit current | 18 A | ||||||
| Number of MPP trackers | 2 | ||||||
| Max. inputs per MPP tracker | 1 | ||||||
| Input (DC Battery) | |||||||
| Compatible battery | LUNA2000-5/10/15-S0, LUNA2000-5/7/10/12/14/15/17/19/21-S1 | ||||||
| Operating voltage range | 350–560 V DC | ||||||
| Max. operating current | 15 A | ||||||
| Max. charge power | 5,000 W | ||||||
| Max. discharge power | 2,200 W | 3,300 W | 3,680 W | 4,400 W | 4,600 W | 5,000 W | 5,000 W |
| Output (On Grid) | |||||||
| Grid connection | Single-phase | ||||||
| Rated output power | 2,000 W | 3,000 W | 3,680 W | 4,000 W | 4,600 W | 5,000 W | 6,000 W |
| Max. apparent power | 2,200 VA | 3,300 W | 3,680 W | 4,400 VA | 5,000 VA | 5,500 W | 6,000 VA |
| Rated output voltage | 220 V AC/230 V AC/240 V AC | ||||||
| Rated AC grid frequency | 50 Hz/60 Hz | ||||||
| Max. output current | 10 A | 15 A | 16 A | 20 A | 23 A | 25 A | 27.3 A |
| Adjustable power factor | 0.8 leading ... 0.8 lagging | ||||||
| Max. total harmonic distortion | ≤ 3% | ||||||
| Power output | Yes (via SmartGuard-63A-S0) | ||||||
| Protection Feature | |||||||
| Anti-islanding protection | Yes | ||||||
| DC reverse polarity protection | Yes | ||||||
| Insulation monitoring | Yes | ||||||
| DC surge protection | Yes, compatible with TYPE II protection class according to EN/IEC 61643-11 | ||||||
| AC surge protection | Yes, compatible with TYPE II protection class according to EN/IEC 61643-11 | ||||||
| Residual current monitoring | Yes | ||||||
| AC overcurrent protection | Yes | ||||||
| AC short-circuit protection | Yes | ||||||
| AC overvoltage protection | Yes | ||||||
| Over-heat protection | Yes | ||||||
| Arc fault protection | Yes | ||||||
| Battery charging from grid | Yes | ||||||
| General Specification | |||||||
| Operating temperature range | -25°C to +60°C (Derated above 45°C @ Rated output power) | ||||||
| Relative operating humidity | 0%–100% RH | ||||||
| Operating altitude | 0–4,000 m (Derated above 2,000 m) | ||||||
| Cooling | Natural convection | ||||||
| Display | LED indicators; integrated WLAN + FusionSolar app | ||||||
| Communication | RS485, WLAN via inverter built-in WLAN module, Ethernet via Smart Dongle-WLAN-FE (Optional); 4G/3G/2G via Smart Dongle-4G (Optional); SA4H-A02 | ||||||
| Weight (incl. mounting brackets) | 12.0 kg (26.5 lb) | ||||||
| Dimensions (incl. mounting brackets) | 365 mm x 375 mm x 156 mm | ||||||
| IP rating | IP65 | ||||||
| Nighttime power | < 2.5 W | ||||||
| Optimizer Compatibility | |||||||
| DC MBUS compatible optimizer | SUN2000-450W-P2, SUN2000-600W-P | ||||||
| Standards Compliance (More Available Upon Request) | |||||||
| Safety | EN/IEC 62109-1, EN/IEC 62109-2 | ||||||
| Grid connection standards | G98, G99, EN 50549-1, CEI 0-21, VDE-AR-N-4105, AS 4777.2, C10/11, ABNT, UTE C15-712, RD 1699, TOR D4, IEC61727, IEC62116 | ||||||
Or contact us immediately: