| Parameter | JUPT-11000K-HD1 | JUPT-7000K-HD1 | JUPT-3000K-HD1 |
|---|---|---|---|
| Input | |||
| Available Inverters / PCS | SUN2000-506KTL-H1/H2/H3 | ||
| Max. MCCB inputs | 24 | 16 | 8 |
| Max. LV AC Inputs | 24 | 16 | 8 |
| AC Power | 12,144 kVA @30°C 11,040 kVA @40°C | 8,096 kVA @30°C 7,360 kVA @40°C | 4,048 kVA @30°C 3,680 kVA @40°C |
| Rated Input Voltage | 1000 V | ||
| LV Panel Segregation | Form 2b | ||
| LV Main Switches (ACB) | 4,000 A, 2 x 1 pcs | 2,900 A, 2 x 1 pcs | 2,900 A, 1 x 1 pcs |
| LV Main Switches (MCCB) | 400 A, 2 x 12 pcs | 400 A, 2 x 8 pcs | 400 A, 8 pcs |
| Output | |||
| Rated Output Voltage Range | 10~35 kV5 | ||
| Frequency | 50 Hz or 60 Hz | ||
| Transformer Type | Oil-immersed, Conservator Type | ||
| Transformer Cooling Type | Mineral Oil: ONAF/ONAN | Mineral Oil: ONAN Natural Ester: KNAN | |
| Transformer Tappings | ± 2 x 2.5% | ||
| Transformer Oil Type | Mineral Oil (PCB Free) | Mineral Oil (PCB Free)/Natural ester oil (Optional) | |
| Transformer Vector Group | Dy11-y11 | Dy11 | |
| Efficiency Index | Tier 2 In accordance with EN 50708 / Full Load Efficiency Index ≥99% | ||
| RMU Type | SF6 Gas Insulated/Natural Gas Insulated6 | ||
| RMU Transformer Protection Unit | MV Vacuum Circuit Breaker Unit | ||
| RMU Cable Incoming / Outgoing Unit | Direct Cable Unit or Cable Load Break Switch Unit | ||
| Auxiliary Transformer | Dry Type Transformer, 8kVA/5kVA, Single-phase, Ii0/50kVA, Three-phase, Dyn11 (Optional) | ||
| Output Voltage of Auxiliary Transformer | Single-phase 230V / 127V , Three-phase 400V or 220V | ||
| Protection | |||
| Transformer Detection & Protection | Oil Level, Oil Temperature, Oil Pressure and Buchholz | ||
| Protection Degree of MV & LV Room | IP 54 | ||
| Internal Arcing Fault of STS | Standard IAC A 20 kA 1s/ IAC A 25 kA 1s | ||
| MV Arc Releasing Protection | MV Upward Arc Releasing for Higher Safety, Meets IEC 62271-202 IAC-A | ||
| LV Arc Protection | Meets IEC 61641 up to Class C arcing protection on LV side, Except for high altitudes | ||
| MV Relay Protection | Standard configuration 50/51, 50N/51N, Inrush Blocking, FR,49T(External trip), 50G/51G(Optional) High configuration adds 74, 86, 27, 59, 79, 59N, 50BF, Inrush Blocking, Watchdog, 49T(External Trip), FR, 87(Optional) | ||
| LV Overvoltage Protection | Type I+II | ||
| Anti-corrosion Protection | C5-M/C5-H7 (Optional) | ||
| Feature | |||
| 2 kVA UPS | Optional8 | ||
| MV Surge Arrester for Transformer | Optional8 | ||
| IMD license | Optional8 | ||
| General | |||
| Dimensions (W × H × D) | 6,058 × 2,896 × 2,438 mm (20' HC ISO Container) | ||
| Weight | < 28 t | < 24 t | < 18 t |
| Operating Temperature Range | -25°C ~ 60°C9 | ||
| Relative Humidity | 0% ~ 95% (Non-condensing) | ||
| Max. Operating Altitude | 1000 m/4,000 m (Option) | ||
| MV-LV AC Connections | Prewired and Pretested, No Internal Cabling Onsite | ||
| LV Room Cooling | Smart Cooling without Air-across for Higher Availability | ||
| Communication | Modbus TCP, Preconfigured with SmartLogger | ||
| Standards Compliance | |||
| Certifications | IEC 62271-202, EN 50708, IEC 60076, IEC 62271-200, IEC 61439-1 | ||
4. More detailed AC power of STS, please refer to the de-rating curve.
5. Rated output voltage from 10 kV to 35 kV, more available upon request.
6. Natural Gas Insulated, up to 24 kV, the switchgear contains the insulating gas Clean Air 0543. Clean Air is a natural gas (Natural-Origin-Gas) according to IEC 62271-4.
7. C5-H is only used in coastal areas with high corrosion.
8. Extra expense needed for optional features which standard product doesn't contain, more options upon request.
9. When ambient temperature ≥55℃, awning shall be equipped for STS on site by customer.