JUPITER-9000K/6000K/3000K-H1(built-in SACU) Schematic Diagram LV Panel RMU Transformer Smart Transformer Station

Daran New Energy Technology Co., Ltd is engaged in solar panels, inverters, battery pack production and sales of manufacturers.

Price

24-hour hotline
+8618031297729

Parameter
JUPITER Series (Built-in SACU) Technical Specifications
ParameterJUPITER-9000K-H1 (Built-in SACU)JUPITER-6000K-H1 (Built-in SACU)JUPITER-3000K-H1 (Built-in SACU)
Input
Available Inverters / PCSSUN2000-330KTL-H1 / SUN2000-330KTL-H2 / LUNA2000-213KTL-H0
Max. MCCB inputs3022121/11
Max. LV AC Inputs602442242/12
AC Power9,000 kVA @40°C36,600 kVA @40°C33,300 kVA @40°C3
Rated Input Voltage800 V
LV Panel SegregationForm 2b
LV Main SwitchesACB (4,000 A, 2 x 1 pcs)
MCCB (400 A, 2 x 15 pcs)4
ACB (2,900 A, 2 x 1 pcs)
MCCB (400 A, 2 x 11 pcs)4
ACB (2,900 A, 1 x 1 pcs)
MCCB (400 A, 11 pcs)4
Output
Rated Output Voltage10~35 kV4
Frequency50 Hz or 60 Hz
Transformer TypeOil-immersed, Conservator Type
Transformer Cooling TypeMineral Oil: ONAN / Natural Ester: KNAN
Transformer Tappings± 2 × 2.5%
Transformer Oil TypeMineral Oil (PCB Free)/Natural ester oil (Optional)
Transformer Vector GroupDy11-y11Dy11
Transformer Min. Peak Efficiency IndexTier 1 or Tier 2 In Accordance with EN 50588-1
RMU TypeSF₆ Gas Insulated
RMU Transformer Protection UnitMV Vacuum Circuit Breaker Unit
RMU Cable Incoming / Outgoing UnitDirect Cable Unit or Cable Load Break Switch Unit
Auxiliary TransformerDry Type Transformer, 5 kVA, Single-phase, li0/50kVA, Three-phase, Dyn11 (Optional)
Output Voltage of Auxiliary Transformer400/230/220/210V
Protection
Transformer Detection & ProtectionOil Level, Oil Temperature, Oil Pressure and Buchholz
Protection Degree of MV & LV RoomIP 54
Internal Arcing Fault of STSStandard IAC A 20 kA 1s/ IAC A 25 kA 1s (Optional)
MV Arc ReleasingMV Upward Arc Releasing for Higher Safety, Meets IEC 62271-202 IAC-A
LV Arc ReleasingMeets IEC 61641 up to Class C arcing protection on LV side
MV Relay ProtectionDVC/CVC Standard 50/51, 50N/51N
DVC/CVC High Standard adds 87, 50BF, Inrush Blocking, Watchdog, 49T (External trip), FR (Optional)
LV Overvoltage ProtectionType I+II
Anti-corrosion ProtectionC5-M
Feature
2 kVA UPSOptional5
MV Surge Arrester for TransformerOptional5
IMD LicenseOptional5
General
Dimensions (W × H × D)6,058 × 2,896 × 2,438 mm (20' HC ISO Container)
Weight< 28 t< 23 t< 17 t
Operating Temperature Range-25°C ~ 60°C6
Relative Humidity0% ~ 95% (Non-condensing)
Max. Operating Altitude1,000 m7
MV-LV AC ConnectionsPrewired and Pretested, No Internal Cabling Onsite
LV Room CoolingSmart Cooling without Air-across for Higher Availability
CommunicationModbus TCP, Preconfigured with SmartACU
Standards Compliance
CertificationsIEC 62271-202, EN 50588-1, IEC 60076, IEC 62271-200, IEC 61439-1, etc.

1. only for GFM version

2. one MCCB can aggregate one inverter and one PCS at the same time, Max. LV AC Inputs means Theoretical number of full-access PCS

3. More detailed AC power of STS, please refer to the de-rating curve.

4. Rated output voltage from 10 kV to 35 kV, more available upon request

5. Extra expense needed for optional features which standard product doesn't contain, more options upon request.

6. When ambient temperature ≥55°C, awning shall be equipped for STS on site by customer.

7. For higher operating altitude, please consult with Huawei.