Parameter


GW Series MT Inverter Technical Data
ParameterGW25K-MTGW29.9K-MTGW30K-MTGW36K-MT
Input
Max. Input Voltage (V)1100110011001100
MPPT Operating Voltage Range (V)200 ~ 950200 ~ 950200 ~ 950200 ~ 950
Start-up Voltage (V)180180180180
Nominal Input Voltage (V)600600600600
Max. Input Current per MPPT (A)30303030
Max. Short Circuit Current per MPPT (A)37.537.537.537.5
Number of MPPT Trackers3333
Number of Strings per MPPT2222
Output
Nominal Output Power (kW)25.029.930.036.0¹
Nominal Output Apparent Power (kVA)25.029.930.036.0¹
Max. AC Active Power (kW)27.5²29.933.0²36.0²
Max. AC Apparent Power (kVA)27.5²29.933.0²36.0²
Nominal Output Voltage (V)400³, 3L / N / PE or 3L / PE400, 3L / N / PE or 3L / PE400³, 3L / N / PE or 3L / PE400³, 3L / N / PE or 3L / PE
Output Voltage Range (V)320 ~ 460320 ~ 460320 ~ 460320 ~ 460
Nominal AC Grid Frequency (Hz)50 / 6050 / 6050 / 6050 / 60
AC Grid Frequency Range (Hz)45 ~ 55 / 55 ~ 6547.5 ~ 51.5 / 57.0 ~ 61.845 ~ 55 / 55 ~ 6545 ~ 55 / 55 ~ 65
Max. Output Current (A)40.043.348.053.3
Power Factor~1 (Adjustable from 0.8 leading to 0.8 lagging)~1 (Adjustable from 0.8 leading to 0.8 lagging)~1 (Adjustable from 0.8 leading to 0.8 lagging)~1 (Adjustable from 0.8 leading to 0.8 lagging)
Max. Total Harmonic Distortion<3%<3%<3%<3%
Efficiency
Max. Efficiency98.7%98.8%98.8%98.8%
European Efficiency98.4%98.5%98.5%98.5%
Protection
PV String Current MonitoringIntegratedIntegratedIntegratedIntegrated
PV Insulation Resistance DetectionIntegratedIntegratedIntegratedIntegrated
Residual Current MonitoringIntegratedIntegratedIntegratedIntegrated
PV Reverse Polarity ProtectionIntegratedIntegratedIntegratedIntegrated
Anti-islanding ProtectionIntegratedIntegratedIntegratedIntegrated
AC Overcurrent ProtectionIntegratedIntegratedIntegratedIntegrated
AC Short Circuit ProtectionIntegratedIntegratedIntegratedIntegrated
AC Overvoltage ProtectionIntegratedIntegratedIntegratedIntegrated
DC SwitchIntegrated⁵Integrated⁵Integrated⁵Integrated⁵
DC Surge ProtectionType III (Type II Optional)Type III (Type II Optional)Type III (Type II Optional)Type III (Type II Optional)
AC Surge ProtectionType III (Type II Optional)Type III (Type II Optional)Type III (Type II Optional)Type III (Type II Optional)
AFCIOptionalOptionalOptionalOptional
Emergency Power OffOptional⁶Optional⁶Optional⁶Optional⁶
Remote ShutdownOptionalOptionalOptionalOptional
PID RecoveryOptionalOptionalOptionalOptional
General Data
Operating Temperature Range (°C)-30 ~ +60-30 ~ +60-30 ~ +60-30 ~ +60
Relative Humidity0 ~ 100%0 ~ 100%0 ~ 100%0 ~ 100%
Max. Operating Altitude (m)3000300030003000
Cooling MethodSmart Fan CoolingSmart Fan CoolingSmart Fan CoolingSmart Fan Cooling
User InterfaceLED, LCD (Optional), WLAN + APPLED, LCD (Optional), WLAN + APPLED, LCD (Optional), WLAN + APPLED, LCD (Optional), WLAN + APP
CommunicationRS485, WiFi or 4G or PLC(Optional)⁷RS485, WiFi or 4G or PLC(Optional)⁷RS485, WiFi or 4G or PLC(Optional)⁷RS485, WiFi or 4G or PLC(Optional)⁷
Communication ProtocolsModbus-RTU (SunSpec Compliant)Modbus-RTU (SunSpec Compliant)Modbus-RTU (SunSpec Compliant)Modbus-RTU (SunSpec Compliant)
Weight (kg)40.040.040.040.0
Dimension (W × H × D mm)480 × 590 × 200480 × 590 × 200480 × 590 × 200480 × 590 × 200
TopologyNon-isolatedNon-isolatedNon-isolatedNon-isolated
Self-consumption at Night (W)<1<1<1<1
Ingress Protection RatingIP65IP65IP65IP65
DC ConnectorMC4 (Max. 6mm²)MC4 (Max. 6mm²)MC4 (Max. 6mm²)MC4 (Max. 6mm²)
AC ConnectorOT / DT Terminal (Max. 25mm²)OT / DT Terminal (Max. 25mm²)OT / DT Terminal (Max. 25mm²)OT / DT Terminal (Max. 25mm²)

¹: 33kW for 96kW for other country.

²: For Brazil and Chile. Max. AC Active Power (kW): GW25K-MT is 25; GW30K-MT is 30; GW36K-MT is 36.

³: For Brazil & Chile Max. AC Apparent Power (kVA): GW25K-MT is 25; GW30K-MT is 30; GW36K-MT is 36.

⁴: For Australia Nominal Output Voltage is 380V, 3L / N / PE or 3L / PE.

⁵: For Australia DC Switch is PV2.

⁶: For Indian Emergency Power Off: Optional.

⁷: For Brazil Communication is RS485, WiFi, USB, PLC (Optional).