| Parameter | GW30K-SDT-C30 | GW30K-SDT-30 | GW33K-SDT-C30 | GW36K-SDT-C30 | GW40K-SDT-C30 | GW40K-SDT-P30 | GW50K-SDT-C30 |
|---|---|---|---|---|---|---|---|
| Input | |||||||
| Max. Input Voltage (V)¹ | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 |
| MPPT Operating Voltage Range (V)² | 140 ~ 1000 | 140 ~ 950 | 140 ~ 1000 | 140 ~ 1000 | 140 ~ 1000 | 140 ~ 1000 | 140 ~ 1000 |
| Start-up Voltage (V) | 160 | 160 | 160 | 160 | 160 | 160 | 160 |
| Nominal Input Voltage (V) | 600 | 600 | 600 | 600 | 600 | 600 | 600 |
| Max. Input Current per MPPT (A) | 42 / 32 | 40 / 40 / 40 | 42 / 42 / 32 | 60 / 42 / 32 | 42 / 42 / 32 | 40 | 40 |
| Max. Short Circuit Current per MPPT (A) | 52.5 / 40 | 50 / 50 / 50 | 52.5 / 52.5 / 40 | 52.5 / 52.5 / 40 | 52.5 / 52.5 / 40 | 56 | 52 |
| Number of MPPT Trackers | 2 | 3 | 3 | 3 | 3 | 4 | 4 |
| Number of Strings per MPPT | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Output | |||||||
| Nominal Output Power (kW) | 30 | 30 | 33 | 36 | 40 | 40 | 50 |
| Nominal Output Apparent Power (kVA) | 30 | 30 | 33 | 36 | 40 | 40 | 50 |
| Max. AC Active Power (kW) | 33 | 30 | 33 | 36 | 40 | 40 | 50 |
| Max. AC Apparent Power (kVA) | 33 | 30 | 33 | 36 | 40 | 40 | 50 |
| Nominal Output Voltage (V) | 220 / 380, 230 / 400, 240 / 415, 3L / N / PE or 3L / PE | ||||||
| Output Voltage Range (V) | 180 ~ 280 | 180 ~ 260 | 180 ~ 280 | 180 ~ 280 | 180 ~ 280 | 180 ~ 280 | 180 ~ 280 |
| Nominal AC Grid Frequency (Hz) | 50 / 60 | 50 / 60 | 50 / 60 | 50 | 50 | 50 / 60 | 50 / 60 |
| AC Grid Frequency Range (Hz) | 45 ~ 55 / 55 ~ 65 | 45 ~ 55 / 55 ~ 65 | 50 | 45 ~ 55 | 45 ~ 55 | 50 / 60 | 45 ~ 55 / 55 ~ 65 |
| Max. Output Current (A) | 50 | 45.5 | 50.1 | 54.6 | 60.7 | 60.6 | 75.7 |
| Power Factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | ||||||
| Max. Total Harmonic Distortion | <3% | ||||||
| Efficiency | |||||||
| Max. Efficiency | 98.6% | 98.7% | 98.6% | 98.6% | 98.6% | 98.6% | 98.7% |
| European Efficiency | 98.3% | 98.3% | 97.8% | 97.8% | 97.8% | 97.7% | 98.0% |
| Protection | |||||||
| PV String Current Monitoring | Integrated | ||||||
| PV Insulation Resistance Detection | Integrated | ||||||
| Residual Current Monitoring | Integrated | ||||||
| PV Reverse Polarity Protection | Integrated | ||||||
| Anti-islanding Protection | Integrated | ||||||
| AC Overcurrent Protection | Integrated | ||||||
| AC Short Circuit Protection | Integrated | ||||||
| AC Overvoltage Protection | Integrated | ||||||
| DC Switch | Integrated | ||||||
| DC Surge Protection | Type III (Type II Optional) | Type II | Type III (Type II Optional) | Type II | Type II | ||
| AC Surge Protection | Type III (Type II Optional) | Type II | Type III (Type II Optional) | Type II | Type II | ||
| AFCI | Optional | ||||||
| Rapid Shutdown | Optional | ||||||
| Remote Shutdown | Integrated | ||||||
| PID Recovery | Optional | ||||||
| Power Supply at Night | Optional | ||||||
| General Data | |||||||
| Operating Temperature Range (°C) | -30 ~ +60 | ||||||
| Relative Humidity | 0 ~ 100% | ||||||
| Max. Operating Altitude (m) | 4000 | ||||||
| Cooling Method | Smart Fan Cooling | ||||||
| User Interface | LED, LCD (Optional), WLAN + APP | ||||||
| Communication | RS485, WiFi + LAN + Bluetooth, 4G + Bluetooth (Optional) | ||||||
| Communication Protocols | Modbus-RTU (SunSpec Compliant), Modbus-TCP | Modbus-RTU | Modbus RTU, Modbus TCP | Modbus-RTU (SunSpec Compliant), Modbus-TCP | |||
| Weight (kg) | 21.1 | 30 | 28 | 28 | 28 | 31 | 33 |
| Dimension (W × H × D mm) | 530 × 413 × 227 | 585 × 483 × 230 | 585 × 483 × 230 | 585 × 483 × 230 | 585 × 483 × 230 | 585 × 483 × 237 | 646 × 484 × 230 |
| Noise Emission (dB) | 45 | 45 | 45 | 45 | 45 | 45 | 50 |
| Topology | Non-isolated | ||||||
| Self-consumption at Night (W) | <1 | ||||||
| Ingress Protection Rating | IP66 | ||||||
| DC Connector | MC4 (4 ~ 6mm²) | ||||||
| AC Connector | OT / DT terminal (Max. 25mm²) | OT / DT terminal (Max. 35mm²) | OT / DT terminal (Max. 70mm²) | ||||
¹: When the input voltage is 1000V-1100V, the inverter will enter standby mode. The inverter will return to normal operation state when the voltage returns to the MPPT working voltage range.
²: Please refer to the user manual for the MPPT Voltage Range at Nominal Power.