| Parameter | GW4000-SDT-30 | GW5000-SDT-30 | GW6000-SDT-30 | GW8000-SDT-30 | GW10K-SDT-30 | GW10K-SDT-EU30 | GW12K-SDT-30 |
|---|---|---|---|---|---|---|---|
| Input | |||||||
| Max. Input Voltage (V)¹ | 1100 | ||||||
| MPPT Operating Voltage Range (V)² | 140 ~ 1000 | ||||||
| Start-up Voltage (V) | 160 | ||||||
| Nominal Input Voltage (V) | 600 | ||||||
| Max. Input Current per MPPT (A) | 22 | ||||||
| Max. Short Circuit Current per MPPT (A) | 27.5 | ||||||
| Number of MPPT Trackers | 2 | ||||||
| Number of Strings per MPPT | 1 | ||||||
| Output | |||||||
| Nominal Output Power (kW) | 4.0 | 5.0 | 6.0 | 8.0 | 10.0 | 10.0 | 12.0 |
| Nominal Output Apparent Power (kVA) | 4.0 | 5.0 | 6.0 | 8.0 | 10.0 | 10.0 | 12.0 |
| Max. AC Active Power (kW) | 4.4 | 5.5 | 6.6 | 8.8 | 11.0 | 10.0 | 13.2 |
| Max. AC Apparent Power (kVA) | 4.4 | 5.5 | 6.6 | 8.8 | 11.0 | 10.0 | 13.2 |
| Nominal Output Voltage (V) | 220 / 380, 230 / 400, 240 / 415, 3L / N / PE or 3L / PE | ||||||
| Output Voltage Range (V) | 180 ~ 280 (according to local standard) | ||||||
| Nominal AC Grid Frequency (Hz) | 50 / 60 | ||||||
| AC Grid Frequency Range (Hz) | 45 ~ 55 / 55 ~ 65 | ||||||
| Max. Output Current (A) | 6.7 | 8.4 | 10.0 | 13.4 | 16.7³ | 15.2 | 20.0 |
| Power Factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | ||||||
| Max. Total Harmonic Distortion | <3% | ||||||
| Efficiency | |||||||
| Max. Efficiency | 98.4% | 98.4% | 98.4% | 98.5% | 98.5% | 98.5% | 98.5% |
| European Efficiency | 97.7% | 97.7% | 97.7% | 98.0% | 98.0% | 98.0% | 98.2% |
| Protection | |||||||
| PV String Current Monitoring | Integrated | ||||||
| PV Insulation Resistance Detection | Integrated | ||||||
| Residual Current Monitoring | Integrated | ||||||
| PV Reverse Polarity Protection | Integrated | ||||||
| Anti-islanding Protection | Integrated | ||||||
| AC Overcurrent Protection | Integrated | ||||||
| AC Short Circuit Protection | Integrated | ||||||
| AC Overvoltage Protection | Integrated | ||||||
| DC Switch | Integrated | ||||||
| DC Surge Protection | Type III (Type II Optional) | ||||||
| AC Surge Protection | Type III (Type II Optional) | ||||||
| AFCI | Optional | ||||||
| Rapid Shutdown | Optional | ||||||
| Remote Shutdown | Integrated | ||||||
| PID Recovery | Optional | ||||||
| Power Supply at Night | Optional | ||||||
| General Data | |||||||
| Operating Temperature Range (°C) | -30 ~ +60 | ||||||
| Relative Humidity | 0 ~ 100% | ||||||
| Max. Operating Altitude (m) | 4000 | ||||||
| Cooling Method | Natural Convection | ||||||
| User Interface | LED, LCD (Optional), WLAN + APP | ||||||
| Communication | RS485, WiFi + LAN + Bluetooth, 4G + Bluetooth (Optional) | ||||||
| Communication Protocols | Modbus-RTU (SunSpec Compliant), Modbus-TCP | ||||||
| Weight (kg) | 15.1 | 15.1 | 15.1 | 15.1 | 15.1 | 15.1 | 16.6 |
| Dimension (W × H × D mm) | 491 × 392 × 210 | 491 × 392 × 210 | |||||
| Noise Emission (dB) | <30 | ||||||
| Topology | Non-isolated | ||||||
| Self-consumption at Night (W) | <1 | ||||||
| Ingress Protection Rating | IP66 | ||||||
| DC Connector | MC4 (4 ~ 6mm²) | ||||||
| AC Connector | OT / DT terminal (Max. 10mm²) | OT / DT terminal (Max. 16mm²) | |||||
¹: When the input voltage is 1000V-1100V, the inverter will enter standby mode. The inverter will return to normal operation state when the voltage returns to the MPPT working voltage range.
²: Please refer to the user manual for the MPPT Voltage Range at Nominal Power.
³: For Jordan, Max. Output Current is 16A.
| Parameter | GW15K-SDT-30 | GW17K-SDT-30 | GW20K-SDT-30 | GW20K-SDT-31 | GW25K-SDT-C30 | GW25K-SDT-30 | GW25K-SDT-P31 |
|---|---|---|---|---|---|---|---|
| Input | |||||||
| Max. Input Voltage (V)¹ | 1100 | ||||||
| MPPT Operating Voltage Range (V)² | 140 ~ 1000 | ||||||
| Start-up Voltage (V) | 160 | ||||||
| Nominal Input Voltage (V) | 600 | ||||||
| Max. Input Current per MPPT (A) | 22 | 32 / 22 | 32 / 22 | 60 / 40 | 42 / 22 | 40 / 40 / 40 | 40 / 40 |
| Max. Short Circuit Current per MPPT (A) | 27.5 | 40 / 27.5 | 40 / 27.5 | 52.5 / 52.5 | 52.5 / 27.5 | 50 / 50 / 50 | 52.5 / 52.5 |
| Number of MPPT Trackers | 2 | 2 | 2 | 2 | 2 | 3 | 2 |
| Number of Strings per MPPT | 1 | 2 / 1 | 2 / 1 | 2 / 2 | 2 / 1 | 2 / 2 | 2 / 2 |
| Output | |||||||
| Nominal Output Power (kW) | 15.0 | 17.0 | 20.0 | 20.0 | 25.0 | 25.0 | 25.0 |
| Nominal Output Apparent Power (kVA) | 15.0 | 17.0 | 20.0 | 20.0 | 25.0 | 25.0 | 25.0 |
| Max. AC Active Power (kW) | 16.5 | 18.7 | 22.0 | 22.0³ | 27.5 | 25.0 | 27.5³ |
| Max. AC Apparent Power (kVA) | 16.5 | 18.7 | 22.0 | 22.0³ | 27.5 | 25.0 | 27.5³ |
| Nominal Output Voltage (V) | 220 / 380, 230 / 400, 240 / 415, 3L / N / PE or 3L / PE | ||||||
| Output Voltage Range (V) | 180 ~ 280 (according to local standard) | ||||||
| Nominal AC Grid Frequency (Hz) | 50 / 60 | ||||||
| AC Grid Frequency Range (Hz) | 45 ~ 55 / 55 ~ 65 | ||||||
| Max. Output Current (A) | 25.0 | 33.3 | 30.3 | 30.3 | 41.7 | 37.9 | 37.9 |
| Power Factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | ||||||
| Max. Total Harmonic Distortion | <3% | ||||||
| Efficiency | |||||||
| Max. Efficiency | 98.5% | 98.5% | 98.5% | 98.5% | 98.6% | 98.7% | 98.5% |
| European Efficiency | 98.2% | 98.2% | 98.2% | 97.9% | 98.2% | 98.3% | 97.9% |
| Protection | |||||||
| PV String Current Monitoring | Integrated | ||||||
| PV Insulation Resistance Detection | Integrated | ||||||
| Residual Current Monitoring | Integrated | ||||||
| PV Reverse Polarity Protection | Integrated | ||||||
| Anti-islanding Protection | Integrated | ||||||
| AC Overcurrent Protection | Integrated | ||||||
| AC Short Circuit Protection | Integrated | ||||||
| AC Overvoltage Protection | Integrated | ||||||
| DC Switch | Integrated | ||||||
| DC Surge Protection | Type III (Type II Optional) | Type III (Type II Optional) | Type II | Type III (Type II Optional) | Type III (Type II Optional) | ||
| AC Surge Protection | Type III (Type II Optional) | Type III (Type II Optional) | Type II | Type III (Type II Optional) | Type III (Type II Optional) | ||
| AFCI | Optional | ||||||
| Rapid Shutdown | Optional | ||||||
| Remote Shutdown | Integrated | ||||||
| PID Recovery | Optional | ||||||
| Power Supply at Night | Optional | ||||||
| General Data | |||||||
| Operating Temperature Range (°C) | -30 ~ +60 | ||||||
| Relative Humidity | 0 ~ 100% | ||||||
| Max. Operating Altitude (m) | 4000 | ||||||
| Cooling Method | Natural Convection | Smart Fan Cooling | |||||
| User Interface | LED, LCD (Optional), WLAN + APP | ||||||
| Communication | RS485, WiFi + LAN + Bluetooth, 4G + Bluetooth (Optional) | ||||||
| Communication Protocols | Modbus-RTU (SunSpec Compliant), Modbus-TCP | Modbus-RTU (SunSpec Compliant), Modbus-TCP | Modbus-RTU (SunSpec Compliant), Modbus-TCP | Modbus RTU, Modbus TCP | Modbus-RTU (SunSpec Compliant), Modbus-TCP | Modbus RTU, Modbus TCP | Modbus RTU, Modbus TCP |
| Weight (kg) | 16.6 | 18.8 | 18.8 | 16.6 | 20.8 | 30.0 | 17.7 |
| Dimension (W × H × D mm) | 491 × 392 × 210 | 530 × 413 × 227 | 530 × 413 × 227 | 530 × 413 × 227 | 585 × 483 × 230 | 585 × 483 × 230 | 530 × 413 × 221 |
| Noise Emission (dB) | <30 | <45 | <45 | <45 | <45 | <45 | <45 |
| Topology | Non-isolated | ||||||
| Self-consumption at Night (W) | <1 | ||||||
| Ingress Protection Rating | IP66 | ||||||
| DC Connector | MC4 (4 ~ 6mm²) | ||||||
| AC Connector | OT / DT terminal (Max. 16mm²) | OT terminal (Max. 25mm²) | OT / DT terminal (Max. 16mm²) | OT / DT terminal (Max. 16mm²) | OT terminal (Max. 25mm²) | OT terminal (Max. 25mm²) | OT / DT terminal (Max. 16mm²) |
¹: When the input voltage is 1000V-1100V, the inverter will enter standby mode. The inverter will return to normal operation state when the voltage returns to the MPPT working voltage range.
²: Please refer to the user manual for the MPPT Voltage Range at Nominal Power.
³: For Sri Lanka, Max. AC Active Power and AC Apparent Power are same as Nominal Output Power.
| Parameter | GW12KLV-SDT-C31 | GW12KLV-SDT-C30 | GW17KLV-SDT-C30 | GW23KLV-SDT-BR30 | GW30KLV-SDT-C30 |
|---|---|---|---|---|---|
| Input | |||||
| Max. Input Voltage (V)¹ | 850 | ||||
| MPPT Operating Voltage Range (V)² | 140 ~ 700 | ||||
| Start-up Voltage (V) | 160 | ||||
| Nominal Input Voltage (V) | 420 | ||||
| Max. Input Current per MPPT (A) | 40 / 40 | 32 / 22 | 42 / 32 | 42 / 42 / 32 | 40 / 40 / 40 / 40 |
| Max. Short Circuit Current per MPPT (A) | 52.5 / 52.5 | 40.0 / 27.5 | 52.5 / 40.0 | 52.5 / 52.5 / 40.0 | 52 / 52 / 52 / 52 |
| Number of MPPT Trackers | 2 | 2 | 2 | 3 | 4 |
| Number of Strings per MPPT | 2/2 | 2/1 | 2 | 2 | 2 |
| Output | |||||
| Nominal Output Power (kW) | 12.0 | 12.0 | 17.0 | 23.0 | 30.0 |
| Max. AC Active Power (kW) | 13.2 | 13.2 | 18.7 | 25.3 | 33.0 |
| Max. AC Apparent Power (kVA) | 13.2 | 13.2 | 18.7 | 25.3 | 33.0 |
| Nominal Output Voltage (V) | 127 / 220, 3L / N / PE or 3L / PE | ||||
| Output Voltage Range (V) | 114 ~ 139 (according to local standard) | ||||
| Nominal AC Grid Frequency (Hz) | 60 | ||||
| AC Grid Frequency Range (Hz) | 59.5 ~ 60.2 | ||||
| Max. Output Current (A) | 31.5 | 33.3 | 50.0 | 60.4 | 78.8 |
| Power Factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | ||||
| Max. Total Harmonic Distortion | <3% | ||||
| Efficiency | |||||
| Max. Efficiency | 98.2% | 98.2% | 97.5% | 97.8% | 98.0% |
| European Efficiency | 97.2% | 97.2% | 96.9% | 97.0% | 97.1% |
| Protection | |||||
| PV String Current Monitoring | Integrated | ||||
| PV Insulation Resistance Detection | Integrated | ||||
| Residual Current Monitoring | Integrated | ||||
| Anti-islanding Protection | Integrated | ||||
| AC Overcurrent Protection | Integrated | ||||
| AC Short Circuit Protection | Integrated | ||||
| AC Overvoltage Protection | Integrated | ||||
| DC Switch | Integrated | ||||
| DC Surge Protection | Type II | Type II | Type II | ||
| AC Surge Protection | Type III (Type II Optional) | Type III (Type II Optional) | Type II | Type II | |
| AFCI | Optional | ||||
| Rapid Shutdown | Optional | ||||
| Remote Shutdown | Integrated | ||||
| PID Recovery | Optional | ||||
| Power Supply at Night | Optional | ||||
| General Data | |||||
| Operating Temperature Range (°C) | -30 ~ +60 | ||||
| Relative Humidity | 0 ~ 100% | ||||
| Max. Operating Altitude (m) | 4000 | ||||
| Cooling Method | Smart Fan Cooling | ||||
| User Interface | LED, LCD (Optional), WLAN + APP | ||||
| Communication | RS485, WiFi + LAN + Bluetooth, 4G + Bluetooth (Optional) | ||||
| Communication Protocols | Modbus RTU, Modbus TCP | ||||
| Weight (kg) | 16.6 | 18.8 | 21.1 | 28.0 | 33.0 |
| Dimension (W × H × D mm) | 530 × 413 × 221 | OT / DT terminal (Max. 35mm²) | OT / DT terminal (Max. 70mm²) | ||
| Noise Emission (dB) | <45 | <45 | <45 | <45 | <50 |
| Topology | Non-isolated | ||||
| Self-consumption at Night (W) | <1 | ||||
| Ingress Protection Rating | IP66 | ||||
| DC Connector | MC4 (4 ~ 6mm²) | ||||
| AC Connector | OT / DT terminal (Max. 16mm²) | OT / DT terminal (Max. 16mm²) | OT / DT terminal (Max. 16mm²) | OT / DT terminal (Max. 35mm²) | OT / DT terminal (Max. 70mm²) |
¹: When the input voltage is 700V-850V, the inverter will enter standby mode. The inverter will return to normal operation state when the voltage returns to the MPPT working voltage range.
²: Please refer to the user manual for the MPPT Voltage Range at Nominal Power.