| Parameter | GW3K-DNS-G40 | GW3.6K-DNS-G40 | GW4.2K-DNS-G40 | GW5K-DNS-G40 | GW6K-DNS-G40 |
|---|---|---|---|---|---|
| Input | |||||
| Max. Input Voltage (V)² | 600 | ||||
| MPPT Operating Voltage Range (V)³ | 40 ~ 560 | ||||
| Start-up Voltage (V) | 50 | ||||
| Nominal Input Voltage (V) | 360 | ||||
| Max. Input Current per MPPT (A) | 20 | ||||
| Max. Short Circuit Current per MPPT (A) | 26 | ||||
| Number of MPPT Trackers | 2 | ||||
| Number of Strings per MPPT | 1 | ||||
| Output | |||||
| Nominal Output Power (W) | 3000 | 3600 | 4200 | 5000 | 6000 |
| Nominal Output Apparent Power (VA) | 3000 | 3600 | 4200 | 5000 | 6000 |
| Max. AC Active Power (W) | 3000 | 3600 | 4200 | 5000 | 6000 |
| Max. AC Apparent Power (VA) | 3000 | 3600 | 4200 | 5000 | 6000 |
| Nominal Output Voltage (V) | 220 / 230 / 240, L / N / PE | ||||
| Output Voltage Range (V) | 196 ~ 311 (according to local standard) | ||||
| Nominal AC Grid Frequency (Hz) | 50 / 60 | ||||
| AC Grid Frequency Range (Hz) | 45 ~ 55 / 55 ~ 65 | ||||
| Max. Output Current (A) | 13.7 | 16.4¹ | 19.1 | 22.8 | 27.3 |
| Power Factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | ||||
| Max. Total Harmonic Distortion | <3% | ||||
| Efficiency | |||||
| Max. Efficiency | 97.2% | 97.2% | 98.1% | 97.4% | 97.4% |
| European Efficiency | 97.2% | 97.2% | 97.3% | 97.3% | 97.3% |
| Protection | |||||
| PV String Current Monitoring | Integrated | ||||
| PV Insulation Resistance Detection | Integrated | ||||
| Residual Current Monitoring | Integrated | ||||
| PV Reverse Polarity Protection | Integrated | ||||
| Anti-islanding Protection | Integrated | ||||
| AC Overcurrent Protection | Integrated | ||||
| AC Short Circuit Protection | Integrated | ||||
| AC Overvoltage Protection | Integrated | ||||
| DC Switch | Integrated (PV II Optional) | ||||
| DC Surge Protection | Type II | ||||
| AC Surge Protection | Type II | ||||
| AFCI | Optional | ||||
| Emergency Power Off | Optional | ||||
| Rapid Shutdown | Optional | ||||
| Remote Shutdown | Optional | ||||
| Power Supply at Night | Optional | ||||
| General Data | |||||
| Operating Temperature Range (°C) | -25 ~ +60 | ||||
| Relative Humidity | 0 ~ 100% | ||||
| Max. Operating Altitude (m) | <4000 | ||||
| Cooling Method | Natural Convection | ||||
| User Interface | LED + LCD / WiFi + APP / Bluetooth + APP | ||||
| Communication | RS485, WIFI, LAN, Bluetooth, 4G | ||||
| Communication Protocols | Modbus, Sunspec | ||||
| Weight (kg) | 9.2 | ||||
| Dimension (W × H × D mm) | 358 × 323 × 165 | ||||
| Noise Emission (dB) | 25 | ||||
| Topology | Non-isolated | ||||
| Self-consumption at Night (W) | <1 | ||||
| Ingress Protection Rating | IP66 | ||||
| DC Connector | MC4 (4 ~ 6mm²) | ||||
| AC Connector | Plug and play connector (Max. 6mm²) | ||||
¹: About GW3.6K-DNS-G40 for the UK market, both nominal output current and max. output current are 16A.
²: When the input voltage ranges from 560V to 600V, the inverter will enter the standby state. When the input voltage returns to the MPPT operating voltage range of 40V to 560V, the inverter will resume normal operating state.
³: Please refer to the user manual for the MPPT Voltage Range at Nominal Power.
Or contact us immediately:
Call Now