DNS G3 Series 3-6kW I Single Phase I 2 MPPTs

Daran New Energy Technology Co., Ltd is engaged in solar panels, inverters, battery pack production and sales of manufacturers.

Price

24-hour hotline
+8618031297729

Parameter
GW Series DNS-30 Inverter Technical Data
ParameterGW3000-DNS-30GW3600-DNS-30GW4200-DNS-30GW5000-DNS-30GW6000-DNS-30
Input
Max. Input Voltage (V)⁷600
MPPT Operating Voltage Range (V)⁸40 ~ 560
Start-up Voltage (V)50
Nominal Input Voltage (V)360
Max. Input Current per MPPT (A)16
Max. Short Circuit Current per MPPT (A)23
Number of MPPT Trackers2
Number of Strings per MPPT1
Output
Nominal Output Power (W)¹300036004200¹50006000
Nominal Output Apparent Power (VA)¹300036004200¹50006000
Max. AC Active Power (W)²33003960⁶4620⁴55006600
Max. AC Apparent Power (VA)²33003960⁶4620⁴55006600
Nominal Output Voltage (V)220 / 230 / 240
Output Voltage Range (V)196 ~ 311
Nominal AC Grid Frequency (Hz)50 / 60
AC Grid Frequency Range (Hz)45 ~ 55 / 55 ~ 65
Max. Output Current (A)⁵14.417.3⁵20.1⁴24.028.8
Power Factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Max. Total Harmonic Distortion<3%
Efficiency
Max. Efficiency97.9%97.9%97.2%97.3%97.4%
European Efficiency97.0%97.0%97.2%97.3%97.4%
Protection
PV String Current MonitoringIntegrated
PV Insulation Resistance DetectionIntegrated
Residual Current MonitoringIntegrated
PV Reverse Polarity ProtectionIntegrated
Anti-islanding ProtectionIntegrated
AC Overcurrent ProtectionIntegrated
AC Short Circuit ProtectionIntegrated
AC Overvoltage ProtectionIntegrated
DC SwitchIntegrated
DC Surge ProtectionType III (Type II Optional)
AC Surge ProtectionType III (Type II Optional)
AFCIOptional
Emergency Power OffOptional
Remote ShutdownOptional
Power Supply at NightOptional
General Data
Operating Temperature Range (°C)-25 ~ +60
Relative Humidity0 ~ 100%
Max. Operating Altitude (m)³4000
Cooling MethodNatural Convection
DisplayLED, LCD (Optional), WLAN + APP
CommunicationWiFi, RS485 or LAN or 4G
Communication ProtocolsModbus RTU, Modbus TCP
Weight (kg)12.812.812.812.813.4
Dimension (W × H × D mm)350 × 410 × 143
Noise Emission (dB)<25
TopologyNon-isolated
Self-consumption at Night (W)<1
Ingress Protection RatingIP66
DC ConnectorMC4 (4 ~ 6mm²)
AC ConnectorPlug and play connector (Max. 6mm²)

¹: For Malaysia GW4200-DNS-30 Nominal Output Power (W) and Nominal Output Apparent Power (VA) is 4200.

²: For Netherlands Max. AC Active Power (W) and Max. AC Apparent Power (VA) GW3600-DNS-30 is 3600, GW4200-DNS-30 is 4200.

³: For Brazil Max. AC Output Current (A) GW3000-DNS-30 is 15.7, GW4200-DNS-30 is 18.3.

⁴: For Chile Max. AC Active Power (W) & Max. AC Apparent Power (VA) GW3000-DNS-30 is 3000, GW3600-DNS-30 is 3600, GW4200-DNS-30 is 4200, GW5000-DNS-30 is 5000, GW6000-DNS-30 is 6000.

⁵: For England Max. Output Current (A) & Nominal Output Current (A) GW3600-DNS-30 is 16A.

⁶: For England Max. AC Active Power (W) & Max. AC Apparent Power (VA) GW3600-DNS-30 is 3600.

⁷: When the input voltage ranges from 560V to 600V, the inverter will enter the standby state. The inverter will resume normal operation state when the voltage returns to the MPPT operating voltage range of 40V to 560V.

⁸: Please refer to the user manual for the MPPT Voltage Range at Nominal Power.