| Models | 23K03 | 25K04 | 30K04 | 36K04 |
|---|---|---|---|---|
| Input DC | ||||
| Max. input voltage | 1100 V | 1100 V | 1100 V | 1100 V |
| Rated voltage | 400 V | 400 V | 400 V | 400 V |
| Start-up voltage | 180 V | 180 V | 180 V | 180 V |
| MPPT voltage range | 180 - 1000 V | |||
| Max. input current | 3 × 42 A | 4 × 42 A | 4 × 42 A | 4 × 42 A |
| Max. short circuit current | 3 × 52.5 A | 4 × 52.5 A | 4 × 52.5 A | 4 × 52.5 A |
| MPPT number / Max. input strings number | 3 / 6 | 4 / 8 | 4 / 8 | 4 / 8 |
| Output AC | ||||
| Rated output power | 23 kW | 25 kW | 30 kW | 36 kW |
| Max. apparent output power | 23 kVA | 25 kVA | 30 kVA | 36 kVA |
| Max. output power | 23 kW | 25 kW | 30 kW | 36 kW |
| Rated grid voltage | 3/PE, 220 V / 230 V | |||
| Rated grid frequency | 50 Hz / 60 Hz | |||
| Rated grid output current | 60.4 A / 57.7 A | 65.6 A / 62.8 A | 78.7 A / 75.3 A | 94.5 A / 90.4 A |
| Max. output current | 60.4 A / 57.7 A | 65.6 A / 62.8 A | 78.7 A / 75.3 A | 94.5 A / 90.4 A |
| Power factor | > 0.99 (0.8 leading - 0.8 lagging) | |||
| THDi | < 3% | |||
| Efficiency | ||||
| Max. efficiency | 97.8% | |||
| EU efficiency | 97.3% | |||
| Protection | ||||
| DC reverse-polarity protection | Yes | |||
| Short circuit protection | Yes | |||
| Output over current protection | Yes | |||
| Surge protection | DC Type II / AC Type II | |||
| Grid monitoring | Yes | |||
| Anti-islanding protection | Yes | |||
| Temperature protection | Yes | |||
| Strings monitoring | Yes | |||
| I/V Curve scanning | Yes | |||
| Multi peak scan | Yes | |||
| Integrated AFCI 2.0 | Optional | |||
| Integrated PID recovery | Optional | |||
| Integrated DC switch | Yes | |||
| General Data | ||||
| Dimensions (W × H × D) | 508 × 612 × 288 mm | |||
| Weight | 32.6 kg | 35.9 kg | 35.9 kg | 36.2 kg |
| Topology | Transformerless | |||
| Self-consumption (night) | < 1 W | |||
| Operating ambient temperature range | -25 ~ +60℃ | |||
| Relative humidity | 0 - 100% | |||
| Ingress protection | IP66 | |||
| Noise emission (typical) | ≤ 55 dB(A) | |||
| Cooling concept | Intelligent fan-cooling | |||
| Max. operation altitude | 4000 m | |||
| Grid connection standard | G98 or G99,VDE-AR-N 4105/VDE V0124,EN50549-1,VDE 0126/UTE C15/VFR:2019,RD 1699/RD 244/UNE 20606/UNE 206007-1,CEI 0-21,C10/11,NRS 097-2-1,TOR,EIFS 2018.2,IEC 62116,IEC 61727,IEC60068,IEC61683,EN 50530 | |||
| Safety / EMC standard | IEC/EN62109-1/-2,IEC/EN61000-6-1/-2/-3/-4 | |||
| Features | ||||
| DC connection | MC4 connector | |||
| AC connection | OT terminal | |||
| Display | LED indicator & Bluetooth + APP | |||
| Communication | RS485, Optional:Wi-Fi, GPRS | |||