S6-EH3P(30-35)K-H-LV(21A)

Daran New Energy Technology Co., Ltd is engaged in solar panels, inverters, battery pack production and sales of manufacturers.

Price

24-hour hotline
+8618031297729

Parameter
Models30K35K
Input DC(PV side)
Recommended max. PV array size60 kW70 kW
Max. usable PV input power60 kW70 kW
Max. input voltage1000 V
Rated voltage600 V
Start-up voltage180 V
MPPT voltage range150 - 850 V
Max. input current3 × 42 A
Max current per DC input42 A
Max. short circuit current3 × 60 A
MPPT number / Max. input strings number3 / 6
Battery
Battery typeLi-ion
Battery voltage range150 - 800 V
Max. charge / discharge current80 A × 2
Number of battery ports2
Max. charge/discharge power of each input33 kW35 kW
CommunicationCAN / RS485
Output AC(Back-up)
Rated output power30 kW35 kW
Max. apparent output power1.6×P,2s1.5×P,10s
Back-up switch time<10 ms
Rated output voltage3/N/PE,127V/220V,133V/230V
Rated frequency50 Hz / 60 Hz
THDv(@linear load)<2%
Input AC(Grid side)
Max. input current152 A / 152 A
Input AC(Generator)
Max. input power30 kW35 kW
Rated input current78.7 A / 75.3 A91.8 A / 87.8 A
Rated input voltage3/N/PE,127V/220V,133V/230V
Rated input frequency50 Hz / 60 Hz
Output AC(Grid side)
Rated output power30 kW35 kW
Max. apparent output power30 kVA35 kVA
Rated grid voltage3/N/PE,127V/220V,133V/230V
Rated grid frequency50 Hz / 60 Hz
Rated grid output current78.7 A / 75.3 A91.8 A / 87.8 A
Power factor>0.99(0.8 leading-0.8 lagging)
THDi<3%
Efficiency
Max efficiency96.3%
EU efficiency95.5%
Battery charged efficiency97.4%
Battery discharged efficiency95.8%
Protection
Surge protectionDC Type II / AC Type II
Output over current protectionYes
Integrated DC switchYes
DC reverse-polarity protectionYes
Protection class / Over voltage categoryI / PV II, battery II, AC III
Integrated AFCI 2.0Optional
General Data
Max. allowable phase imbalance(grid & back-up)100%
Max. power per phase(grid & back-up)33% rated power
Dimensions(W×H×D)530 × 880 × 290 mm
Weight76 kg
TopologyTransformerless
Operating ambient temperature range-25 ~ +60℃
Relative humidity0 - 100%
Ingress protectionIP66
Cooling conceptIntelligent fan-cooling
Max. operation altitude4000 m
Grid connection standardG99,VDE-AR-N4105,EN50549等
Safety / EMC standardIEC/EN62109-1/-2,IEC/EN61000-6-2/-4,EN55011
Features
PV connectionMC4 connector
Battery connectionTerminal connector
AC connectionOT terminal
Display7.0" LCD display & Bluetooth + APP
CommunicationCAN,RS485-115200;Optional:Wi-Fi,Cellular,LAN
Describe
Enhanced Floating Chat
Live Support ×

Or contact us immediately:

Call Now
(On desktop: select & copy number)