| Models | 29.9K | 30K | 40K | 49K | 50K | 60K |
|---|---|---|---|---|---|---|
| Input DC (PV side) | ||||||
| Recommended max. PV array size | 59.8 kW | 60 kW | 80 kW | 98 kW | 100 kW | 100 kW |
| Max. usable PV input power | 59.8 kW | 60 kW | 80 kW | 98 kW | 100 kW | 100 kW |
| Max. input voltage | 1000 V | |||||
| Rated voltage | 600 V | |||||
| Start-up voltage | 180 V | |||||
| MPPT voltage range | 150 - 850 V | |||||
| Max. input current | 3 × 42 A | 4 × 42 A | ||||
| Max. current per DC input | 42 A | |||||
| Max. short circuit current | 3 × 60 A | 4 × 60 A | ||||
| MPPT number / Max. input strings number | 3 / 6 | 4 / 8 | ||||
| Battery | ||||||
| Battery type | Li-ion | |||||
| Battery voltage range | 150 - 800 V | |||||
| Max. charge / discharge current | 80 A × 2 | 84 A × 2 | ||||
| Number of battery port / Number of BMS port | 2 | |||||
| Max. charge / discharge current of each port | 80 A | 84 A | ||||
| Communication | CAN / RS485 | |||||
| Output AC (Grid side) | ||||||
| Rated output power | 29.9 kW | 30 kW | 40 kW | 49 kW | 50 kW | 60 kW |
| Max. apparent output power | 29.9 kVA | 30 kVA | 40 kVA | 49 kVA | 50 kVA | 60 kVA |
| Rated grid voltage | 3/N/PE,220 V / 380 V,230 V / 400 V | |||||
| Rated grid frequency | 50 Hz / 60 Hz | |||||
| Rated grid output current | 45.4 A / 43.2 A | 45.6 A / 43.3 A | 60.8 A / 57.7 A | 74.5 A / 70.7 A | 76 A / 72.2 A | 91.2 A / 86.6 A |
| Power factor | > 0.99 (0.8 leading - 0.8 lagging) | |||||
| THDi | < 3% | |||||
| Input AC (Grid side) | ||||||
| Max. input power | 59.8 kW | 60 kW | 60 kW | 98 kW | 100 kW | 100 kW / 105 kW |
| Input voltage range | 304 - 460 V | |||||
| Max. input current | 90.8 A / 86.4 A | 91.2 A / 86.6 A | 121.6 A / 115.4 A | 149 A / 141.4 A | 152 A / 144.4 A | 152 A / 152 A |
| Output AC (Back-up) | ||||||
| Rated output power | 29.9 kW | 30 kW | 40 kW | 49 kW | 50 kW | 60 kW |
| Max. apparent output power | 1.6 times of rated power, 2 s; | 1.5 times of rated power, 10 s | ||||
| Back-up switch time ① | < 10 ms | |||||
| Rated output voltage | 3/N/PE,220 V / 380 V,230 V / 400 V | |||||
| Rated frequency | 50 Hz / 60 Hz | |||||
| Rated output current | 45.4 A / 43.2 A | 45.6 A / 43.3 A | 60.8 A / 57.7 A | 74.5 A / 70.7 A | 76 A / 72.2 A | 91.2 A / 86.6 A |
| Max. AC passthrough current | 45.4 A / 43.2 A | 45.6 A / 43.3 A | 60.8 A / 57.7 A | 74.5 A / 70.7 A | 76 A / 72.2 A | 91.2 A / 86.6 A |
| THDv(@linear load) | < 2% | |||||
| Input AC (Generator side) | ||||||
| Max. input power | 29.9 kW | 30 kW | 40 kW | 49 kW | 50 kW | 60 kW |
| Rated input current | 45.4 A / 43.2 A | 45.6 A / 43.3 A | 60.8 A / 57.7 A | 74.5 A / 70.7 A | 76 A / 72.2 A | 91.2 A / 86.6 A |
| Rated input voltage | 3/N/PE,220 V / 380 V,230 V / 400 V | |||||
| Rated input frequency | 50 Hz / 60 Hz | |||||
| Efficiency | ||||||
| Max. efficiency | 97.7% | |||||
| EU efficiency | 97.3% | |||||
| BAT charged by PV / AC max. efficiency | 98.5% / 97.8% | |||||
| Battery discharged efficiency | 97.5% | |||||
| Protection | ||||||
| Surge protection | DC Type II / AC Type II | |||||
| Output over current protection | Yes | |||||
| Insulation resistance monitoring | Yes | |||||
| Residual current detection | Yes | |||||
| Integrated PV switch | Yes | |||||
| DC reverse-polarity protection | Yes | |||||
| Protection class / Over voltage category | I / PV II, battery II, AC III | |||||
| Integrated AFCI 2.0 | Optional | |||||
| Anti-islanding protection | Yes | |||||
| General Data | ||||||
| Max. power per phase(grid & back-up) | 33% rated power | |||||
| Dimensions (W × H × D) | 530 × 880 × 290 mm | |||||
| Weight | 76 kg | |||||
| Inverter topology | Transformerless | |||||
| Self-consumption | < 35 W | |||||
| Operating temperature range | -25 ~ +60℃ | |||||
| Relative humidity | 0 - 100% | |||||
| Ingress protection | IP66 | |||||
| Cooling concept | Intelligent redundant fan-cooling | |||||
| Max. operation altitude | 4000 m | |||||
| Grid connection standard ② | G99,VDE-AR-N 4105/VDE V0124,EN 50549-1/EN 50549-10,PTPIIRE,VDE 0126/XP C15/VFR:2019,NTS 631/RD 1699/UNE 217002,CEI 0-21,CEI 0-16,C10/11,NRS 097-2-1,TOR,EIFS 2018,2,IEC 62116,IEC 61727,DEWA,MEA,PEA,PORTARIA Nº140/PORTARIA Nº 515 | |||||
| Safety / EMC standard | IEC/EN 62109-1/-2,IEC/EN61000-6-2/-4,EN 55011 | |||||
| Features | ||||||
| PV connection | MC4 connector | |||||
| Battery connection | Terminal connector | |||||
| AC connection | OT terminal | |||||
| Display | 7.0" LCD display & Bluetooth + APP | |||||
| Communication interface | Standard:WIFI+LAN+Bluetooth,CAN-BMS×2,CAN-Parallel×2,RS485-Meter,RS485,DRM,DI×3,DO×3;Optional:4G | |||||
| ① From On-Grid Mode to Off-Grid Mode: For a single inverter system, switchtime <10ms. For a parallel system which consists of up to 6 inverters, switchtime <20ms. If customer wishes to connect more than 6 inverters in parallel, please contact Solis Technical Team. | ||||||
| ② This column only showed the planned certification standards. Please confirm the specific time of obtaining the standards with the local team. | ||||||