S6-EH3P(8-12)K-LV-ND-H

Daran New Energy Technology Co., Ltd is engaged in solar panels, inverters, battery pack production and sales of manufacturers.

Price

24-hour hotline
+8618031297729

Parameter
Models8K10K12K
Input DC (PV side)
Recommended max. PV array size16 kW20 kW24 kW
Max. usable PV input power12.8 kW16 kW19.2 kW
Max. input voltage1000 V
Rated voltage600 V
Start-up voltage160 V
MPPT voltage range200 - 850 V
Max. input current4 × 16 A4 × 20 A
Max. short circuit current4 × 24 A4 × 30 A
MPPT number / Max. input strings number4 / 4
Battery
Battery typeLi-ion
Battery voltage range120 - 800 V
Max. charge / discharge power8 kW10 kW12 kW
Max. charge / discharge current50 A
CommunicationCAN / RS485
Output AC (Grid side)
Rated output power8 kW10 kW12 kW
Max. apparent output power8 kVA10 kVA12 kVA
Rated grid voltage3/(N)/PE,133 V / 230 V
Rated grid frequency50 Hz / 60 Hz
Rated grid output current20.1 A25.1 A30.1 A
Max. output current20.1 A25.1 A30.1 A
Power factor> 0.99 (0.8 leading - 0.8 lagging)
THDi< 3%
Input AC (Grid side)
Input voltage range184 - 265 V
Max. input current30.1 A37.7 A45.2 A
Rated grid frequency50 Hz / 60 Hz
Frequency range45 - 55 Hz / 55 - 65 Hz
Input Generator
Max. input power8 kW10 kW12 kW
Max. input current20.1 A25.1 A30.1 A
Rated input frequency50 Hz / 60 Hz
Output AC (Back-up)
Rated output power8 kW10 kW12 kW
Max. apparent output power1.6 times of rated power, 10 s
Back-up switch time< 10 ms
Rated output voltage3/(N)/PE,133 V / 230 V
Rated frequency50 Hz / 60 Hz
Rated output current20.1 A25.1 A30.1 A
THDv(@linear load)< 2%
Efficiency
Max. efficiency96.70%
EU efficiency96.39%
BAT charged by PV max. efficiency96.23%
BAT charged / discharged to AC max. efficiency96.43%
Protection
Anti-islanding protectionYes
Output over current protectionYes
Short circuit protectionYes
Integrated AFCI 2.0Optional
Integrated DC switchYes
DC reverse-polarity protectionYes
PV over voltage protectionYes
Battery reverse protectionYes
General Data
Max. allowable phase imbalance (grid & back-up)100%
Max. power per phase (grid & back-up)40% rated power
Dimensions (W × H × D)563 × 546 × 235 mm
Weight32.6 kg
TopologyTransformerless
Self-consumption (night)< 25 W
Operating ambient temperature range-25 ~ +60℃
Relative humidity0 - 100%
Ingress protectionIP66
Noise emission (typical)< 65 dB(A)
Cooling conceptIntelligent fan-cooling
Max. operation altitude4000 m
Grid connection standardEN 50549-1/-10, VDE4105, REN342
Safety / EMC standardIEC/EN 62109-1/-2, IEC/EN61000-6-1/-2/-3/-4
Features
PV connectionMC4 connector
Battery connectionOT terminal
AC connectionOT terminal
DisplayLED indicator & Bluetooth + APP
CommunicationCAN, RS485, Ethernet, Optional: Wi-Fi, Cellular, LAN