| Models | 9.6K | 10K | 11.4K | 12K | 14K | 16K |
|---|---|---|---|---|---|---|
| Input DC (PV side) | ||||||
| Recommended max. PV power | 15.36 kW | 16 kW | 18.24 kW | 19.2 kW | 22.4 kW | 25.6 kW |
| Max. input voltage | 550 V | |||||
| Rated voltage | 380 V | |||||
| Start-up voltage | 100 V | |||||
| MPPT voltage range | 160-450 V | 186-450 V | ||||
| Full load MPPT voltage range | 100-450 V | |||||
| Max. input current per MPPT | 40 A | |||||
| Max. short circuit current per MPPT | 50 A | |||||
| Number of MPPTs / Number of strings per MPPT | 3 / 2 | |||||
| Battery | ||||||
| Battery type | Li-ion/Lead-acid | |||||
| Battery voltage range | 40 - 60 V | |||||
| Max. charge / discharge current | 200 A | 208 A | 237.5 A | 250 A | 250 A | 290 A |
| Communication | CAN / RS485 | |||||
| Number of batteries per inverter | See Battery Compatibility Sheet | |||||
| Output AC (Grid side) | ||||||
| Rated output power | 9.6 kW | 10 kW | 11.4 kW | 12 kW | 14 kW | 16 kW |
| Max. apparent output power | 9.6 kVA | 10 kVA | 11.4 kVA | 12 kVA | 14 kVA | 16 kVA |
| Rated output voltage | 220 V / 240 V | |||||
| Rated grid frequency | 50 Hz / 60 Hz | |||||
| Rated grid output current | 43.6 A / 40 A | 45.5 A / 41.7 A | 51.8 A / 47.5 A | 54.5 A / 50 A | 63.6 A / 58.3 A | 72.7 A / 66.7 A |
| Max. output current | 43.6 A / 40 A | 45.5 A / 41.7 A | 51.8 A / 47.5 A | 54.5 A / 50 A | 63.6 A / 58.3 A | 72.7 A / 66.7 A |
| THDi | <3% | |||||
| Input AC (Grid side) | ||||||
| Input voltage range | 193.6-242 V / 211-264 V | |||||
| Max. input current | 200 A | |||||
| Frequency range | 59.5 - 60.5 Hz / 58.8 - 61.2 Hz | |||||
| Output AC (Back-up and Off-grid) | ||||||
| Rated output power | 9.6 kW | 10 kW | 11.4 kW | 12 kW | 14 kW | 16 kW |
| Max. apparent output power | 2 time of rated power, 10 s; 3 times of rated power, 1 s | |||||
| Back-up switch time | <10 ms | |||||
| Phase power | L1/L2/N(PE),220 V / 240 V (split phase) | |||||
| Rated output voltage | 220 V / 240 V | |||||
| AC output voltage range | 193.6-242 V / 211-264 V | |||||
| Rated grid frequency | 50 Hz / 60 Hz | |||||
| Rated output current | 43.6 A / 40 A | 45.5 A / 41.7 A | 51.8 A / 47.5 A | 54.5 A / 50 A | 63.6 A / 58.3 A | 72.7 A / 66.7 A |
| Max. output over current protection,10 sec | 87.2 A / 80 A | 91 A / 83.4 A | 103.6 A / 95 A | 109 A / 100 A | 127.2 A / 116.6 A | 145.4 A / 133.4 A |
| Max. continuous AC passthrough | 200 A | |||||
| Allowable phase imbalance | 50% | |||||
| Backup support configurations | Dedicated loads and whole-home | |||||
| Power factor | >0.99 (0.8 leading - 0.8 lagging) | |||||
| THDv(@linear load) | <3% | |||||
| Input Generator | ||||||
| Max. input power | 30 kW | |||||
| Max. input current | 125 A | |||||
| Rated input frequency | 50 Hz / 60 Hz | |||||
| Efficiency | ||||||
| Max. efficiency | 96.02% | |||||
| CEC efficiency | 95.45% | |||||
| Battery charged by PV max. efficiency | 96.21% | |||||
| Battery charged / discharged to AC max. efficiency | 94.16%/94.22% | |||||
| Protection | ||||||
| Ground fault monitoring | Yes | |||||
| Integrated AFCI | Yes | |||||
| DC reverse-polarity protection | Yes (PV only) | |||||
| Rapid shutdown NEC 2017 | Integrated SunSpec-certified Transmitter | |||||
| Compatible RSD receivers | See MLRSD compatibility Sheet | |||||
| Protection class / Over voltage category | I / II | |||||
| General Data | ||||||
| Dimensions (W × H × D) | 21.02 × 36.61 × 11.69 in (534 × 930 × 297 mm) | |||||
| Weight | 145.06 lbs (65.8 kg) | |||||
| Topology | Transformerless | |||||
| Operating ambient temperature range | -13℉ to 140℉ (-25℃ to 60℃) | |||||
| Ingress protection | TYPE 4X (IP66) | |||||
| Self-consumption (night) | <35 W | |||||
| Noise emission (typical) | <65 dB(A) | |||||
| Cooling concept | Intelligent fan-cooling | |||||
| Relative humidity range | 0 - 100% | |||||
| Mounting type | Wall Bracket | |||||
| Max. operation altitude | 13120 ft (4000 m) | |||||
| Grid Certifications | IEEE 1547-2018,IEEE1547-1-2020,CA Rule 21,SRD 2.0 | |||||
| Safety Certifications | UL 1741 PVRS, UL 1698B, UL 1998,UL 1741, UL 1741 SB, CSA C22.2107.1-1 | |||||
| Emissions | FCC Part 15 Class B | |||||
| Features | ||||||
| DC connection | Terminal Block (PV port) / Terminal Block (BAT port) | |||||
| AC connection | Terminal Block | |||||
| Interface | 7.0" LCD display & Bluetooth + APP | |||||
| Revenue grade meter | Optional | |||||
| Monitoring platform | SolisCloud (modbus map and API sharing available upon request) | |||||
| Communication | RS485, Optional: Cellular, Wi-Fi, LAN | |||||