| Datasheet | SPE 3500TL HVM-24G2 | SPE 5000TL HVM-G2 | SPE 6000TL HVM-G2 | SPE 7000TL HVM-G2 |
|---|---|---|---|---|
| Input data (DC) | ||||
| Max. recommended PV power (for module STC) | 4000W | 5000W | 8000W | 8000W |
| Start voltage | 80±5V | |||
| MPP voltage range | 60V–450V | |||
| No. of MPP trackers | 1 | 1 | 2 | 2 |
| No. of PV strings per MPP tracker | 1 | 1 | 2 | 2 |
| Max. input current per MPP tracker | 22A | 22A | 16A+16A | 16A+16A |
| Max. DC voltage | 500V | |||
| Max. short-circuit current per MPP trackers | 28A | 28A | 22A+22A | 22A+22A |
| Output data (AC) | ||||
| AC nominal power | 3500W | 5000W | 6000W | 7000W |
| Max. AC apparent power | 3500VA | 5000VA | 6000VA | 7000VA |
| Output current | 15.2A | 21.8A | 26.1A | 30.4A |
| Nominal AC voltage | 208V/220V/230V/240V | |||
| AC grid frequency | 50/60Hz | |||
| Adjustable power factor | 0.8leading...0.8lagging | |||
| THDi | <5% | |||
| Battery data (DC) | ||||
| Nominal DC voltage | 24V | 48V | 48V | 48V |
| Battery voltage range | 20–32V | 40–60V | 40–60V | 40–60V |
| Battery overcharge protection | 32V | 60V | 60V | 60V |
| Backup power (AC) | ||||
| AC nominal output power | 3500W | 5000W | 6000W | 7000W |
| Nominal AC output voltage | 230V | |||
| Nominal AC output frequency | 50/60Hz | |||
| Switch time | 10ms typical, Max@20ms | 10ms typical, RCD 20ms Max@Single <30ms @ Parallel | ||
| Efficiency | ||||
| Peak efficiency | 96.5% | |||
| European efficiency | 95.5% | |||
| General data | ||||
| Dimensions (W / H / D) | 370/430/125mm | 370/430/125mm | 422/460/125mm | 422/460/125mm |
| Weight | 10.5kg | 10.8kg | 13.5kg | 13.8kg |
| Operating temperature range | -20℃ ... +50℃ | |||
| Topology | Transformerless | |||
| Cooling | DC fan | |||
| Protection degree | IP20 | |||
| Relative humidity | 5%~95% non-considering | |||
| Altitude | <2000m | |||
| Communication | WIFI/4G | |||
Or contact us immediately:
Call Now