| Datasheet | MIN 2500TL-XH2 | MIN 3000TL-XH2 | MIN 3600TL-XH2 | MIN 4200TL-XH2 | MIN 4600TL-XH2 | MIN 5000TL-XH2 | MIN 6000TL-XH2 |
|---|---|---|---|---|---|---|---|
| Input data (DC) | |||||||
| Max. recommended PV power (for module STC) | 5000W | 6000W | 7200W | 8400W | 9200W | 10000W | 10000W |
| Max. DC voltage | 500V | 500V | 550V | 550V | 550V | 550V | 550V |
| Start voltage | 50V | ||||||
| Nominal voltage | 360V | ||||||
| MPP voltage range | 40V–490V | 40V–490V | 40V–540V | 40V–540V | 40V–540V | 40V–540V | 40V–540V |
| No. of MPP trackers/strings per MPP tracker | 2/1 | ||||||
| Max. input current per MPP tracker | 16A | ||||||
| Max. short-circuit current per MPP trackers | 24A | ||||||
| Input data (DC battery) | |||||||
| Compatible battery | ARK XH Battery System (5.12kWh–17.9kWh), APX 5.0-30.0P-S0 (5kWh–30kWh) | ||||||
| Operating voltage range | 360–500V | 360–500V | 360–550V | 360–550V | 360–550V | 360–550V | 360–550V |
| Max.operating current | 17A | ||||||
| Max.charge power | 2500W | 3000W | 3600W | 4200W | 4600W | 5000W | 6000W |
| Max.discharge power | 2500W | 3000W | 3600W | 4200W | 4600W | 5000W | 6000W |
| Output data (AC) | |||||||
| AC nominal power | 2500W | 3000W | 3600W | 4200W | 4600W | 5000W | 6000W |
| Max. AC apparent power | 2500VA | 3000VA | 3600VA | 4200VA | 4600VA | 5000VA | 6000VA |
| Nominal AC voltage (range) | 230V (180–280V) | ||||||
| AC grid frequency (range) | 50/60 Hz (45–55Hz/55–65Hz) | ||||||
| Max. output current | 11.3A | 13.6A | 16A | 19A | 20.9A | 22.7A | 27.2A |
| Adjustable power factor | 0.8leading...0.8lagging | ||||||
| THDi | <3% | ||||||
| AC grid connection type | Single phase | ||||||
| Output data (Backup*) | |||||||
| Max. apparent power | 2500VA | 3000VA | 3600VA | 4200VA | 4600VA | 5000VA | 6000VA |
| Nominal AC voltage | 230V | ||||||
| AC grid frequency | 50/60Hz | ||||||
| Efficiency | |||||||
| Max.efficiency | 98.2% | 98.2% | 98.2% | 98.4% | 98.4% | 98.4% | 98.4% |
| European efficiency | 97.1% | 97.1% | 97.2% | 97.2% | 97.5% | 97.5% | 97.5% |
| MPPT efficiency | 99.9% | ||||||
| Protection devices | |||||||
| DC reverse polarity protection | Yes | ||||||
| DC switch | Yes | ||||||
| DC/AC surge protection | Type II/Type III | ||||||
| Insulation resistance monitoring | Yes | ||||||
| AC short-circuit protection | Yes | ||||||
| Ground fault monitoring | Yes | ||||||
| Grid monitoring | Yes | ||||||
| Anti-islanding protection | Yes | ||||||
| Residual-current monitoring unit | Yes | ||||||
| AFCI protection | Optional | ||||||
| General data | |||||||
| Dimensions (W / H / D) | 375/350/160mm | ||||||
| Weight | 10.8kg | ||||||
| Operating temperature range | -30℃~+60℃ | ||||||
| Altitude | 4000m | ||||||
| Self-consumption night | <3W | ||||||
| Topology | Transformerless | ||||||
| Cooling | Natural convection | ||||||
| Protection degree | IP66 | ||||||
| Relative humidity | 0%~100% | ||||||
| DC connection | H4/MC4(Optional) | ||||||
| AC connection | Connector | ||||||
| Display | OLED+LED/WIFI+APP | ||||||
| Interfaces: RS485/USB/WIFI/GPRS/RF/LAN | Yes/Yes/Optional/Optional/Optional/Optional | ||||||
| Warranty: 5 years / 10 years | Yes/Optional | ||||||
| CE, UKCA,IEC62109,AS/NZS4777.2, CEI0-21, VDE-AR-N4105, VDE 0126-1-1,UTE C15-712-1,EN50549-1, IEC 62116, IEC 61727, G98/G99,UNE217001, UNE206007, PO12.2 | |||||||
| * The AC voltage and frequency range may varying depending on specific country grid standard. All specifications are subject to change without notice. * Backup power function need a SYN 50-XH-10. * AFCI function need to be activated after installation. | |||||||
Or contact us immediately: